Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/111263
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSchartner, E.-
dc.contributor.authorHenderson, M.-
dc.contributor.authorPurdey, M.-
dc.contributor.authorMonro, T.-
dc.contributor.authorGill, P.-
dc.contributor.authorCallen, D.-
dc.contributor.editorChung, Y.-
dc.contributor.editorJin, W.-
dc.contributor.editorLee, B.-
dc.contributor.editorCanning, J.-
dc.contributor.editorNakamura, K.-
dc.contributor.editorYuan, L.-
dc.date.issued2017-
dc.identifier.citationProceedings of SPIE, 2017 / Chung, Y., Jin, W., Lee, B., Canning, J., Nakamura, K., Yuan, L. (ed./s), vol.10323, pp.103230X-1-103230X-4-
dc.identifier.isbn151061091X-
dc.identifier.isbn9781510610910-
dc.identifier.issn0277-786X-
dc.identifier.issn1996-756X-
dc.identifier.urihttp://hdl.handle.net/2440/111263-
dc.description.abstractWe report the development of an optical fibre probe which could find use as an aid for margin detection during surgery. A fluorophore doped polymer is coated on an optical fibre tip, allowing for pH values of unknown tissue to be measured and compared to healthy tissue, to discriminate between healthy and cancerous tissue. This probe is integrated within a portable system, requiring no alignment or access to specialised vibration damped optical tables. A miniature spectrometer allows for measurements to be performed on-site, opening up the potential for use of these probes within the operating theatre for in-vivo measurements.-
dc.description.statementofresponsibilityErik P. Schartner, Matthew R. Henderson, Malcolm Purdey, Tanya M. Monro, P. Grantley Gill, and David F. Callen-
dc.language.isoen-
dc.publisherSPIE Press-
dc.relation.ispartofseriesProceedings of SPIE-
dc.rights© 2017 SPIE-
dc.source.urihttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/10323.toc-
dc.subjectOptical fibre sensors; pH; fluorescence; oncology; breast cancer; melanoma-
dc.titleA portable device for cancer margin assessment using a pH sensitive optical fibre probe-
dc.typeConference paper-
dc.contributor.conferenceInternational Conference on Optical Fiber Sensors (OFS) (24 Apr 2017 - 28 Apr 2017 : Jeju, Korea)-
dc.identifier.doi10.1117/12.2263263-
dc.publisher.placeOnline-
dc.relation.granthttp://purl.org/au-research/grants/arc/LP110200736-
pubs.publication-statusPublished-
dc.identifier.orcidSchartner, E. [0000-0003-1669-4302]-
dc.identifier.orcidPurdey, M. [0000-0002-5063-8972]-
dc.identifier.orcidGill, P. [0000-0001-7310-2970]-
dc.identifier.orcidCallen, D. [0000-0002-6189-9991]-
Appears in Collections:Aurora harvest 3
IPAS publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.