Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/135262
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBhanushali, A.-
dc.contributor.authorChimutengwende-Gordon, N.-
dc.contributor.authorBeck, M.-
dc.contributor.authorCallary, S.A.-
dc.contributor.authorCosti, K.-
dc.contributor.authorHowie, D.W.-
dc.contributor.authorSolomon, L.B.-
dc.date.issued2021-
dc.identifier.citationBone and Joint Journal, 2021; 103-B(11):1662-1668-
dc.identifier.issn2049-4394-
dc.identifier.issn2049-4408-
dc.identifier.urihttps://hdl.handle.net/2440/135262-
dc.description.abstractAIMS: The aims of this study were to compare clinically relevant measurements of hip dysplasia on radiographs taken in the supine and standing position, and to compare Hip2Norm software and Picture Archiving and Communication System (PACS)-derived digital radiological measurements. METHODS: Preoperative supine and standing radiographs of 36 consecutive patients (43 hips) who underwent periacetabular osteotomy surgery were retrospectively analyzed from a single-centre, two-surgeon cohort. Anterior coverage (AC), posterior coverage (PC), lateral centre-edge angle (LCEA), acetabular inclination (AI), sharp angle (SA), pelvic tilt (PT), retroversion index (RI), femoroepiphyseal acetabular roof (FEAR) index, femoroepiphyseal horizontal angle (FEHA), leg length discrepancy (LLD), and pelvic obliquity (PO) were analyzed using both Hip2Norm software and PACS-derived measurements where applicable. RESULTS: Analysis of supine and standing radiographs resulted in significant variation for measurements of PT (p < 0.001) and AC (p = 0.005). The variation in PT correlated with the variation in AC in a limited number of patients (R2 = 0.378; p = 0.012). CONCLUSION: The significant variation in PT and AC between supine and standing radiographs suggests that it may benefit surgeons to have both radiographs when planning surgical correction of hip dysplasia. We also recommend using PACS-derived measurements of AI and SA due to the poor interobserver error on Hip2Norm.-
dc.description.statementofresponsibilityAmeya Bhanushali, Mukai Chimutengwende-Gordon, Martin Beck, Stuart Adam Callary, Kerry Costi, Donald W. Howie, Lucian Bogdan Solomon-
dc.language.isoen-
dc.publisherBritish Editorial Society of Bone and Joint Surgery-
dc.rights© 2021 The British Editorial Society of Bone & Joint Surgery-
dc.source.urihttp://dx.doi.org/10.1302/0301-620x.103b11.bjj-2020-2519.r2-
dc.subjectDevelopmental dysplasia of the hip-
dc.subjectperiacetabular osteotomy-
dc.subjectStanding vs supine-
dc.subjectHip dysplasia-
dc.subjectHip2Norm-
dc.subjectWeightbearing-
dc.subjectRadiographs-
dc.subjecthips-
dc.subjectDevelopmental dysplasia of the hip (DDH)-
dc.subjectlateral centre-edge angle (LCEA)-
dc.subjectpelvic tilt-
dc.subjectleg length discrepancy-
dc.subjectpelvic obliquity-
dc.subjectacetabular roof-
dc.subjectfemoral heads-
dc.subject.meshHumans-
dc.subject.meshHip Dislocation-
dc.subject.meshRadiography-
dc.subject.meshRetrospective Studies-
dc.subject.meshSupine Position-
dc.subject.meshAdolescent-
dc.subject.meshAdult-
dc.subject.meshMiddle Aged-
dc.subject.meshFemale-
dc.subject.meshMale-
dc.subject.meshYoung Adult-
dc.subject.meshStanding Position-
dc.titleThe variation in hip stability measurements between supine and standing radiographs of dysplastic hips-
dc.typeJournal article-
dc.identifier.doi10.1302/0301-620X.103B11.BJJ-2020-2519.R2-
pubs.publication-statusPublished-
dc.identifier.orcidCallary, S.A. [0000-0002-2892-5238]-
dc.identifier.orcidHowie, D.W. [0000-0003-1702-3279]-
dc.identifier.orcidSolomon, L.B. [0000-0001-6254-2372]-
Appears in Collections:Orthopaedics and Trauma publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.