Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/138889
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: A phase 1/2, open-label, parallel group study to evaluate the safety and pharmacokinetics of DARE-HRT1 (80 μg estradiol/4 mg progesterone and 160 μg estradiol/8 mg progesterone intravaginal rings) over 12 weeks in healthy postmenopausal women
Author: Thurman, A.
Hull, M.L.
Stuckey, B.
Hatheway, J.
Zack, N.
Mauck, C.
Friend, D.
Citation: Menopause: The Journal of the North American Menopause Society, 2023; 30(8):817-823
Publisher: Ovid Technologies (Wolters Kluwer Health)
Issue Date: 2023
ISSN: 1072-3714
1530-0374
Statement of
Responsibility: 
Andrea Thurman, Louise Hull, Bronwyn Stuckey, Jessica Hatheway, Nadene Zack, Christine Mauck and David Friend
Abstract: Objectives: Primary objectives were to evaluate the safety and systemic pharmacokinetics (PK) of DARE-HRT1, an intravaginal ring (IVR), which releases 17β2-Estradiol (E2) with progesterone (P4) for 28 days in healthy postmenopausal women. Methods: This was a randomized, open-label, 2-arm, parallel group study in 21 healthy postmenopausal women with an intact uterus. Women were randomized (1:1) to either DARE-HRT1 IVR1 (E2 80 μg/d with P4 4 mg/d) or DARE-HRT1 IVR2 (E2 160 μg/d with P4 8 mg/d). They used the IVR for three 28-day cycles, inserting a new IVR monthly. Safety was measured by treatment emergent adverse events and changes in systemic laboratories and the endometrial bilayer width. Baseline adjusted plasma PK of E2, P4, and estrone (E1) was described. Results: Both DARE-HRT1 IVR were safe. All treatment emergent adverse events were mild or moderate and were distributed similarly among IVR1 versus IVR2 users. Month 3 median maximum plasma (Cmax) P4 concentrations were 2.81 and 3.51 ng/mL and Cmax E2 was 42.95 and 77.27 pg/mL for IVR1 and IVR2 groups, respectively. Month 3 median steady state (Css) plasma P4 concentrations were 1.19 and 1.89 ng/mL, and Css E2 was 20.73 and 38.16 pg/mL for IVR1 and IVR2 users, respectively. Conclusions: Both DARE-HRT1 IVRs were safe and released E2 in systemic concentrations, which were in the low, normal premenopausal range. Systemic P4 concentrations predict endometrial protection. Data from this study support further development of DARE-HRT1 for the treatment of menopausal symptoms.
Keywords: Intravaginal ring; Menopausal symptoms; Pharmacokinetics; Safety; Vasomotor symptoms
Description: Published August 2023
Rights: © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of The North American Menopause Society. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
DOI: 10.1097/gme.0000000000002210
Published version: http://dx.doi.org/10.1097/gme.0000000000002210
Appears in Collections:Obstetrics and Gynaecology publications

Files in This Item:
File Description SizeFormat 
hdl_138889.pdfPublished version434.67 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.