Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/35222
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHan, S.-
dc.contributor.authorJahns, T.-
dc.contributor.authorGuven, M.-
dc.contributor.authorAydin, M.-
dc.contributor.authorSoong, W.-
dc.contributor.editorMark Halpin,-
dc.date.issued2006-
dc.identifier.citationConference Record of the 2006 IEEE Industry Applications Conference, 41st IAS Annual Meeting:pp.1962-1969-
dc.identifier.isbn1424403642-
dc.identifier.issn0197-2618-
dc.identifier.urihttp://hdl.handle.net/2440/35222-
dc.description.abstractInterior permanent magnet (IPM) synchronous machines are vulnerable to uncontrolled generator (UCG) faults at high speed that can damage the inverter. One approach to reducing this risk is to impose limits on the maximum machine back-EMF voltage at top speed. This paper presents the results of a comparative design study that clarifies the nature and extent of the penalties imposed on the IPM machine metrics and performance characteristics as a result of imposing progressively tighter values of back-EMF voltage limits. As an alternative to limiting back-EMF and penalizing machine designs, this paper also investigates the effectiveness of the system-side protection approach to the same UCG fault problem.-
dc.description.statementofresponsibilitySeok-hee Han, Thomas M. Jahns, Metin Aydin, Mustafa K. Guven, Wen L. Soong-
dc.language.isoen-
dc.publisherIEEE-
dc.relation.ispartofseriesIEEE Industry Applications Society Annual Meeting-
dc.rightsCopyright © 2006 IEEE-
dc.source.urihttp://dx.doi.org/10.1109/ias.2006.256804-
dc.subjectinterior permanent magnet synchronous machine; IPM; uncontrolled generator faults; UCG; back-emf limit-
dc.titleImpact of maximum back-EMF limits on the performance characteristics of interior permanent magnet synchronous machines-
dc.typeConference paper-
dc.contributor.conferenceIndustry Applications Conference. Annual Meeting. (41st : 2006 : Tampa, Florida)-
dc.identifier.doi10.1109/IAS.2006.256804-
pubs.publication-statusPublished-
dc.identifier.orcidSoong, W. [0000-0003-0734-7608]-
Appears in Collections:Aurora harvest 6
Electrical and Electronic Engineering publications
Environment Institute publications

Files in This Item:
File Description SizeFormat 
hdl_35222.pdf776.3 kBAuthor's post-printView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.