Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/43150
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Bimodal electric tissue ablation (BETA) - in-vivo evaluation of the effect of applying direct current before and during radiofrequency ablation of porcine liver
Author: Cockburn, J.
Maddern, G.
Wemyss-Holden, S.
Citation: Clinical Radiology, 2007; 62(3):213-220
Publisher: W B Saunders Co Ltd
Issue Date: 2007
ISSN: 0009-9260
1365-229X
Statement of
Responsibility: 
J.F. Cockburn, G.J. Maddern and S.A. Wemyss-Holden
Abstract: <h4>Aim</h4>To examine the effect of applying increasing amounts of direct current (DC) before and during alternating current radiofrequency ablation of porcine liver.<h4>Materials and methods</h4>Using a Radiotherapeutics RF3000 generator, a 9 V AC/DC transformer and a 16 G plain aluminium tube as an electrode, a control group of 24 porcine hepatic radiofrequency ablation zones was compared with 24 zones created using a bimodal electric tissue ablation (BETA) technique in three pigs. All ablations were terminated when tissue impedance rose to greater than 999 Omega or radiofrequency energy input fell below 5 W on three successive measurements taken at 1 min intervals. BETA ablations were performed in two phases: an initial phase of variable duration DC followed by a second phase during which standard radiofrequency ablation was applied simultaneously with DC. During this second phase, radiofrequency power input was regulated by the feedback circuitry of the RF3000 generator according to changes in tissue impedance. The diameters (mm) of each ablation zone were measured by two observers in two planes perpendicular to the plane of needle insertion. The mean short axis diameter of each ablation zone was subjected to statistical analysis.<h4>Results</h4>With increased duration of prior application of DC, there was a progressive increase in the diameter of the ablation zone (p<0.001). This effect increased sharply up to 300 s of pre-treatment after which a further increase in diameter occurred, but at a much lesser rate. A maximum ablation zone diameter of 32 mm was produced (control diameters 10-13 mm).<h4>Conclusion</h4>Applying a 9 V DC to porcine liver in vivo, and continuing this DC application during subsequent radiofrequency ablation, results in larger ablation zone diameters compared with radiofrequency ablation alone.
Keywords: Liver
Animals
Swine
Catheter Ablation
Hepatectomy
Needles
Time Factors
Description: Copyright © 2006 The Royal College of Radiologists Published by Elsevier Ltd.
DOI: 10.1016/j.crad.2006.11.008
Description (link): http://www.elsevier.com/wps/find/journaldescription.cws_home/623019/description#description
Published version: http://dx.doi.org/10.1016/j.crad.2006.11.008
Appears in Collections:Aurora harvest
Surgery publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.