Please use this identifier to cite or link to this item:
https://hdl.handle.net/2440/51815
Citations | ||
Scopus | Web of Science® | Altmetric |
---|---|---|
?
|
?
|
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Withayachumnankul, W. | - |
dc.contributor.author | Fischer, B. | - |
dc.contributor.author | Abbott, D. | - |
dc.date.issued | 2008 | - |
dc.identifier.citation | Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2008; 464(2097):2435-2456 | - |
dc.identifier.issn | 1364-5021 | - |
dc.identifier.issn | 1471-2946 | - |
dc.identifier.uri | http://hdl.handle.net/2440/51815 | - |
dc.description.abstract | The use of T-rays, or terahertz radiation, to identify substances by their spectroscopic fingerprints is a rapidly moving field. The dominant approach is presently terahertz time-domain spectroscopy. However, a key problem is that ambient water vapour is ubiquitous and the consequent water absorption distorts the T-ray pulses. Water molecules in the gas phase selectively absorb incident T-rays at discrete frequencies corresponding to their molecular rotational transitions. When T-rays propagate through an atmosphere, this results in prominent resonances spread over the T-ray spectrum; furthermore, in the time domain, fluctuations after the main pulse are observed in the T-ray signal. These effects are generally undesired, since they may mask critical spectroscopic data. So, ambient water vapour is commonly removed from the T-ray path by using a closed chamber during the measurement. Yet, in some applications, a closed chamber is not always feasible. This situation, therefore, motivates the need for an optional alternative method for reducing these unwanted artefacts. This paper represents a study on a computational means that is a step towards addressing the problem arising from water vapour absorption over a moderate propagation distance. Initially, the complex frequency response of water vapour is modelled from a spectroscopic catalogue. Using a deconvolution technique, together with fine tuning of the strength of each resonance, parts of the water vapour response are removed from a measured T-ray signal, with minimal signal distortion, thus providing experimental validation of the technique. © 2008 The Royal Society. | - |
dc.description.statementofresponsibility | Withawat Withayachumnankul, Bernd M Fischer and Derek Abbott | - |
dc.language.iso | en | - |
dc.publisher | Royal Soc London | - |
dc.source.uri | http://dx.doi.org/10.1098/rspa.2007.0294 | - |
dc.title | Numerical removal of water-vapour effects from THz-TDS measurements | - |
dc.type | Journal article | - |
dc.identifier.doi | 10.1098/rspa.2007.0294 | - |
pubs.publication-status | Published | - |
dc.identifier.orcid | Withayachumnankul, W. [0000-0003-1155-567X] | - |
dc.identifier.orcid | Abbott, D. [0000-0002-0945-2674] | - |
Appears in Collections: | Aurora harvest Electrical and Electronic Engineering publications |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.