Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/52270
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Type: Journal article
Title: The biologic response to particles from a potential disc prosthesis material
Author: Shimamura, Y.
Holding, C.
Haynes, D.
Vernon-Roberts, B.
Blumbergs, P.
Fraser, R.
Moore, R.
Citation: Spine, 2008; 33(4):351-355
Publisher: Lippincott Williams & Wilkins
Issue Date: 2008
ISSN: 0362-2436
1528-1159
Statement of
Responsibility: 
Shimamura, Yoshio; Holding, Christopher; Haynes, David R.; Vernon-Roberts, Barrie; Blumbergs, Peter C.; Fraser, Robert D.; Moore, Robert J.
Abstract: <h4>Study design</h4>An in vivo study of material from a potential disc prosthesis.<h4>Objective</h4>To examine the histopathologic effect of particulate debris on the dura and neural tissue in sheep.<h4>Summary of background data</h4>Disc prostheses are emerging as alternatives to spinal fusion for the treatment of symptomatic degenerative lumbar disc disease. Preclinical biocompatibility trials must be conducted before any device is considered for general use.<h4>Methods</h4>Artificially generated wear particles of a material known as Sinux (DePuy Spine, Raynham, MA) were implanted directly onto the lumbosacral dura and nerve roots of 18 sheep that were randomly allocated to 3 groups to survive between 1 and 6 months. Tissue sections from T12 to the sacrum were examined for histopathological evidence of inflammation and wound healing in response to the particles and for the effects on the neural elements.<h4>Results</h4>There was no significant evidence of inflammation, macrophage accumulation, or other tissue response. Other observations included some minor tissue pigmentation due to microhemorrhage, occasional but minimal lymphocyte infiltration, and crystalline Sinux in the fibroadipose connective tissue external to the dura.<h4>Conclusion</h4>Artificially generated particles of Sinux placed directly onto the dura and nerve roots did not induce any significant biologic response in a sheep model.
Keywords: Dura Mater
Spinal Nerve Roots
Animals
Sheep
Foreign-Body Reaction
Inflammation
Elastomers
Biocompatible Materials
Microscopy, Electron, Scanning
Prosthesis Implantation
Random Allocation
Equipment Failure Analysis
Materials Testing
Models, Animal
Implants, Experimental
Wound Healing
Particle Size
Intervertebral Disc
DOI: 10.1097/BRS.0b013e318163f323
Published version: http://dx.doi.org/10.1097/brs.0b013e318163f323
Appears in Collections:Aurora harvest
Pathology publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.