Please use this identifier to cite or link to this item:
https://hdl.handle.net/2440/53467
Citations | ||
Scopus | Web of Science® | Altmetric |
---|---|---|
?
|
?
|
Type: | Journal article |
Title: | Comparing patients' and clinicians' assessment of outcomes in a randomised trial of sentinel node biopsy for breast cancer (the RACS SNAC trial) |
Author: | Smith, M. Gill, P. Wetzig, N. Sourjina, T. Gebski, V. Ung, O. Campbell, I. Kollias, J. Coskinas, X. Macphee, A. Young, L. Simes, R. Stockler, M. |
Citation: | Breast Cancer Research and Treatment, 2009; 117(1):99-109 |
Publisher: | Kluwer Academic Publ |
Issue Date: | 2009 |
ISSN: | 0167-6806 1573-7217 |
Statement of Responsibility: | Michaella J. Smith, P. Grantley Gill, Neil Wetzig, Tatiana Sourjina, Val Gebski, Owen Ung, Ian Campbell, James Kollias, Xanthi Coskinas, Avis Macphee, Leonie Young, R. John Simes, Martin R. Stockler and The Royal Australasian College of Surgeons SNAC Trial Group |
Abstract: | The RACS sentinel node biopsy versus axillary clearance (SNAC) trial compared sentinel-node-based management (SNBM) and axillary lymph-node dissection (ALND) for breast cancer. In this sub study, we sought to determine whether patient ratings of arm swelling, symptoms, function and disability or clinicians’ measurements were most efficient at detecting differences between randomized groups, and therefore, which of these outcome measures would minimise the required sample sizes in future clinical trials. 324 women randomised to SNBM and 319 randomised to ALND were included. The primary endpoint of the trial was percentage increase in arm volume calculated from clinicians’ measurements of arm circumference at 10 cm intervals. Secondary endpoints included reductions in range of motion and sensation (both measured by clinicians); and, patients’ ratings of arm swelling, symptoms and quality of life, using the European Organisation for Research and Treatment of Cancer Breast Cancer Module (EORTC QLM-BR23), the body image after breast cancer questionnaire (BIBC) and the SNAC study specific scales (SSSS). The relative efficiency (RE, the squared ratio of the test statistics, with 95% confidence intervals calculated by bootstrapping) was used to compare these measures in detecting differences between the treatment groups. Patients’ self-ratings of arm swelling were generally more efficient than clinicians’ measurements of arm volume in detecting differences between treatment groups. The SSSS arm symptoms scale was the most efficient (RE = 7.1) The entire SSSS was slightly less so (RE = 4.6). Patients’ ratings on single items were 3–5 times more efficient than clinicians’ measurements. Primary endpoints based on patient-rated outcome measures could reduce the required sample size in future surgical trials. |
Keywords: | Axillary lymph node dissection Breast cancer Randomized clinical trial Outcomes assessment Lymphoedema Sentinel node biopsy Quality of life Relative efficiency statistic |
Description: | The original publication can be found at www.springerlink.com |
DOI: | 10.1007/s10549-008-0202-3 |
Published version: | http://dx.doi.org/10.1007/s10549-008-0202-3 |
Appears in Collections: | Aurora harvest 5 Surgery publications |
Files in This Item:
There are no files associated with this item.
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.