Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/55749
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Bioelectrical phase angle values in a clinical sample of ambulatory rehabilitation patients
Author: Gunn, S.
Halbert, J.
Giles, L.
Stepien, J.
Miller, M.
Crotty, M.
Citation: Dynamic medicine : DM, 2008; 7(14):1-8
Publisher: BioMed Central Ltd
Issue Date: 2008
ISSN: 1476-5918
1476-5918
Statement of
Responsibility: 
Simon M. Gunn, Julie A. Halbert, Lynne C. Giles, Jacqueline M. Stepien, Michelle D. Miller and Maria Crotty
Abstract: Background: Phase angle (PhA) is derived from the resistance and reactance measurements obtained from bioelectric impedance analysis (BIA) and is considered indicative of cellular health and membrane integrity. This study measured PhA values of rehabilitation patients and compared them to reference values, measures of functional ability and serum C-reactive protein (CRP) levels to explore their utility as a clinical tool to monitor disease progression and treatment efficacy. Methods: This cross-sectional observational study was conducted on 215 ambulatory rehabilitation patients aged 20 – 94 years. All participants had been hospitalised for a stroke, orthopaedic or other condition resulting in a functional limitation. PhA was derived from BIA analysis and functional ability characterised using the Functional Independence Measure (FIM), timed up and go (TUG) and maximal quadriceps strength (MQS). Serum levels of CRP were also collected. Results: Stroke patients had the highest PhA (5.3°) followed by elective orthopaedic surgery (5.0°) with the other group (4.3°) significantly lower than both previous categories (p < 0.001). Ambulatory rehabilitation patients' PhA values were dependent on age and sex (p < 0.001), lower than published age matched healthy reference values (p ≤ 0.05) and similar to other hospitalised or sick groups, but also higher than values reported in critically ill patients. Patients with CRP values less than 10 mg.L-1 had significantly (p = 0.005) higher mean PhA values. Furthermore, the highest functional status quartiles had significantly higher PhAs (p ≤ 0.04) for the FIM, MQS and TUG measures. Conclusion: The results suggest that the phase angles of rehabilitation patients are between those of healthy individuals and seriously ill patients, thereby supporting claims that PhA is indicative of general health status. Phase angles are a potentially useful indicator of functional status in patients commencing an ambulatory rehabilitation program with a normal hydration status.
Rights: © 2008 Gunn et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
DOI: 10.1186/1476-5918-7-14
Published version: http://dx.doi.org/10.1186/1476-5918-7-14
Appears in Collections:Aurora harvest
Obstetrics and Gynaecology publications

Files in This Item:
File Description SizeFormat 
hdl_55749.pdfPublished version397.11 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.