Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/58771
Citations
Scopus Web of Science® Altmetric
?
?
Type: Conference paper
Title: Accuracy test for in-vitro micro-computed tomography
Author: Stoico, R.
Tassani, S.
Perilli, E.
Baruffaldi, F.
Viceconti, M.
Citation: IFMBE proceedings, 2009 / Dossel, O., Schlegel, W.C. (ed./s), vol.25 IFMBE, iss.4, pp.410-413
Publisher: Springer
Publisher Place: Germany
Issue Date: 2009
Series/Report no.: IFMBE Proceedings ; 25/4
ISBN: 9783642038815
ISSN: 1680-0737
1433-9277
Conference Name: World Congress on Medical Physics and Biomedical Engineering (WC) (7 Sep 2009 - 12 Sep 2009 : Munich, Germany)
Editor: Dossel, O.
Schlegel, W.C.
Statement of
Responsibility: 
R. Stoico, S. Tassani, E. Perilli, F. Baruffaldi and M. Viceconti
Abstract: The present work aims to describe and discuss the application of an accuracy test for in-vitro micro-computed tomography (microCT). Accuracy of morphometric measures is required to the analysis of bone microstructure and the mechanical characterization of the tissue. The accuracy test was introduced in a program of quality control designed for trabecular bone morphometry. It was applied using a physical calibration phantom that reproduced the three-dimensional structure of the typically investigated object, i.e. trabecular bone structure. The phantom was used to test the quality of accuracy measurements. The absolute error was chosen as the quality control parameter in accuracy test. The Shewhart control chart was introduced to monitor the quality control parameter. Baseline value was calculated as reference value for the control chart during acceptance/status test. An out of control condition was defined as the monthly measure that was out of the tolerance limits determined by the adopted chart. A maintenance service has been suggested upon the occurrence of this condition. During the monitoring period of 15-months no out of control conditions in accuracy test were recorded, as confirmed by the statistical C and Kruskal Wallis tests. Thus, by application of the accuracy test, the performance of the microCT system was found to be in control.
Keywords: X-ray microtomography
accuracy test
phantoms
Rights: © Springer
DOI: 10.1007/978-3-642-03882-2_109
Published version: http://dx.doi.org/10.1007/978-3-642-03882-2_109
Appears in Collections:Aurora harvest 5
Pathology publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.