Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/62946
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMeswania, J. M.en
dc.contributor.authorBousdras, V. A.en
dc.contributor.authorAhir, S. P.en
dc.contributor.authorCunningham, J. L.en
dc.contributor.authorBlunn, Gordon W.en
dc.contributor.authorGoodship, Allen Edwarden
dc.date.issued2010en
dc.identifier.citationProceedings of the Institution of Mechanical Engineers Part H - Journal of Engineering in Medicine, 2010; 224(10):1221-1232en
dc.identifier.issn0954-4119en
dc.identifier.urihttp://hdl.handle.net/2440/62946-
dc.description.abstractThe degree of osseomechanical integration of dental implants is acutely sensitive to their mechanical environment. Bone, both as a tissue and structure, adapts its mass and architecture in response to loading conditions. Therefore, application of predefined controlled loads may be considered as a treatment option to promote early maturation of bone/implant interface prior to or in conjunction with crown/prosthesis attachment. Although many studies have established that the magnitude, rate of the applied strain, and frequency have significant effects on the osteogenic response, the actual specific relationships between strain parameters and frequency have not yet been fully defined. The purpose of this study was to develop a stimulator to apply defined mechanical stimuli to individual dental implants in vivo immediately after implantation, exploring the hypothesis that immediate controlled loading could enhance implant integration. An electromechanical device was developed, based on load values obtained using a two-dimensional finite element analysis of the bone/implant interface generating 1000 to 4000 με and operated at 30 and 3 Hz respectively. The device was then tested in a cadaveric pig mandible, and periosteal bone surface strains were recorded for potential future comparison with a three-dimensional finite element model to determine loading regimens to optimize interface strains and iterate the device for clinical use.en
dc.description.statementofresponsibilityJ M Meswania, V A Bousdras, S P Ahir, J L Cunningham, G W Blunn and A E Goodshipen
dc.language.isoenen
dc.publisherProfessional Engineering Publishing Ltden
dc.rightsCopyright ©2010, MetaPress. All Rights Reserved.en
dc.subjectdental implant; osseointegration; osteogenic stimuli; bone enhancement; biophysical forcesen
dc.titleA novel closed-loop electromechanical stimulator to enhance osseointegration with immediate loading of dental implant restorationsen
dc.typeJournal articleen
dc.contributor.schoolSchool of Medical Sciences : Pathologyen
dc.identifier.doi10.1243/09544119JEIM686en
Appears in Collections:Pathology publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.