Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/63221
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorNoll, L.-
dc.contributor.authorRommel, N.-
dc.contributor.authorDavidson, G.-
dc.contributor.authorOmari, T.-
dc.date.issued2011-
dc.identifier.citationNeurogastroenterology and Motility, 2011; 23(6):551-E206-
dc.identifier.issn1350-1925-
dc.identifier.issn1365-2982-
dc.identifier.urihttp://hdl.handle.net/2440/63221-
dc.description.abstract<h4>Background</h4>The role of pharyngeal impedance recording for assessing pharyngeal function is yet to be established. The aim of this study was to evaluate impedance flow interval, a novel parameter, in relation to bolus residue and the occurrence of aspiration. The effect of catheter configuration was also assessed.<h4>Methods</h4>We studied 12 children (1.8-13.5years) with cerebral palsy, who were all referred for a videofluoroscopy due to suspected aspiration risk. Pharyngeal impedance patterns during bolus swallowing were recorded simultaneously with fluoroscopy. Two different catheter configurations were used: Catheter 1, 1.9mm diameter with 1cm electrodes and Catheter 2, 3.2mm diameter with 2cm electrodes. The flow interval was based on the objective assessment of impedance drop and recovery across multiple impedance segments and was correlated with fluoroscopic evidence of postswallow bolus residue and deglutitive aspiration.<h4>Key results</h4>One hundred and thirty two liquid swallows were evaluated. Patient swallows with aspiration compared to those without aspiration had a longer flow interval (Cath 1 P=0.005; Cath 2 P<0.001). Patient swallows with residue had a longer flow interval, however this was only significant for swallows recorded using Catheter 2 (P=0.004). Multiple logistic regressions showed that higher flow interval was a better marker of the presence of aspiration [odds ratio (OR) 13.4 (3.0, 59.2); P<0.001] than the presence of residue [OR 3.8 (1.4, 10.3); P=0.01].<h4>Conclusions & inferences</h4>We present novel findings suggesting that impedance measurement can detect alterations in flow characteristics of pharyngeal swallow that have the potential to predict to deglutitive aspiration risk.-
dc.description.statementofresponsibilityL. Noll, N. Rommel, G. P. Davidson, T. I. Omari-
dc.language.isoen-
dc.publisherBlackwell Publishing Ltd-
dc.rights© 2010 Blackwell Publishing Ltd.-
dc.source.urihttp://dx.doi.org/10.1111/j.1365-2982.2010.01634.x-
dc.subjectaspiration-
dc.subjectbolus residue-
dc.subjectdeglutition-
dc.subjectdiagnosis-
dc.subjectdysphagia-
dc.subjectimpedance.-
dc.titlePharyngeal flow interval: a novel impedance-based parameter correlating with aspiration-
dc.typeJournal article-
dc.identifier.doi10.1111/j.1365-2982.2010.01634.x-
pubs.publication-statusPublished-
dc.identifier.orcidOmari, T. [0000-0001-5108-7378]-
Appears in Collections:Aurora harvest
Paediatrics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.