Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/64556
Citations
Scopus Web of Science® Altmetric
?
?
Type: Conference paper
Title: Decision process for comparison of partial and complete XANES spectra
Author: Zheng, J.
Edraki, M.
Huynh, T.
Gasparon, M.
Ng, J.
Harris, H.
Noller, B.
Citation: SRI 2009 : the 10th International Conference on Synchrotron Radiation Instrumentation / R. Garrett, I. Gentle, K. Nugent, S. Wilkins (eds.): pp.621-624
Publisher: AIP
Publisher Place: USA
Issue Date: 2010
Series/Report no.: AIP Conference Proceedings
ISBN: 9780735407824
ISSN: 0094-243X
1551-7616
Conference Name: International Conference on Synchrotron Radiation Instrumentation (10th : 2009 : Melbourne, Australia)
Editor: Garrett, R.
Gentle, I.
Nugent, K.
Wilkins, S.
Statement of
Responsibility: 
J. J. Zheng, M. Edraki, T. Huynh, M. Gasparon, J. Ng, H. H. Harris, and B. Noller
Abstract: If the range of XANES spectra varies between sets of scans, it may be impossible to compare sets of spectra unless a restricted part of the spectra is used. The paper derives a decision process for comparison of partial and complete XANES spectra, taking lead as an example. Lead L3-edge XANES spectra were collected at the Australian National Beamline Facility (BL-20B) Photon Factory, Tsukuba, Japan over the energy range 13,000-13,150 eV (ring conditions: 2.5 GeV, 300-400 mA). The monochromator step size was reduced to 0.25 eV per step in the XANES region (13,000-13,100 eV and 13,040-13,100 eV) to collect high-resolution spectra. XANES data for samples and model compounds were collected at ambient temperature and pressure in fluorescence, using simultaneous collection of a Pb metal reference foil for energy calibration (first derivative peak of elemental Pb was 13,050 eV). XANES spectra were fitted using spectral deconvolution and least-squares linear combination fitting (LCF). Detailed XANES results with LCF approach over various energy ranges are illustrated and discussed and show the applicability of the decision-making procedure to compare sets of spectra. © 2010 American Institute of Physics.
Keywords: X-ray absorption spectra
X-ray fluorescence
X-ray diffraction
Description: Also published as: AIP Conference Proceedings, 2010; 1234(1):621-624
Rights: ©2010 American Institute of Physics
DOI: 10.1063/1.3463283
Published version: http://dx.doi.org/10.1063/1.3463283
Appears in Collections:Aurora harvest
Environment Institute publications
Physics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.