Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/66872
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Toric intraocular lens outcome using the manufacturer's prediction of corneal plane equivalent intraocular lens cylinder power
Author: Goggin, M.
Moore, S.
Esterman, A.
Citation: JAMA Ophthalmology, 2011; 129(8):1004-1008
Publisher: Amer Medical Assoc
Issue Date: 2011
ISSN: 0003-9950
1538-3601
Statement of
Responsibility: 
Michael Goggin, Sacha Moore, Adrian Esterman
Abstract: Objectives: To describe the refractive outcome of toric intraocular lens (IOL) implantation by comparing the postoperative refractive astigmatism with the preoperative keratometric astigmatism target. Method: In a university department of a publicly funded hospital, 38 eyes of 29 patients underwent routine cataract surgery with insertion of a toric implant (SN60TT AcrySof Toric). Surgically induced astigmatism was derived using vector analysis of refractive outcome vs predicted postoperative keratometric astigmatism and compared with the targeted induced astigmatism. Results: Postoperative remaining refractive astigmatism of 0.97 diopters (D) was achieved vs a target of 0.61 D. A mean (SD) surgically induced astigmatism value of 1.78 (0.89) D was derived compared with a mean (SD) targeted induced astigmatism value of 1.58 (0.47) D (calculated by the manufacturer's online calculator, which predicts IOL corneal plane equivalent cylinder power and postoperative keratometric cylinder). Conclusions: Toric IOLs are a safe, predictable method of astigmatic correction. However, some remaining astigmatism is commonly present owing to the necessary nonzero astigmatic targets imposed by the steps between IOL cylinder powers, variability of axis, and power effects of surgical incisions as well as by underestimation of the corneal plane cylinder power of the IOLs by the manufacturer.
Keywords: Cornea
Humans
Astigmatism
Postoperative Complications
Pseudophakia
Refraction, Ocular
Treatment Outcome
Preoperative Care
Phacoemulsification
Lens Implantation, Intraocular
Lenses, Intraocular
Visual Acuity
Manufactured Materials
Aged
Female
Male
Optics and Photonics
Rights: ©2011 American Medical Association. All rights reserved.
DOI: 10.1001/archophthalmol.2011.178
Published version: http://dx.doi.org/10.1001/archophthalmol.2011.178
Appears in Collections:Aurora harvest
Opthalmology & Visual Sciences publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.