Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/68326
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Double motion of upper eyelids in Graves' orbitopathy: An additional sign for detection of thyroid dysfunction or positive thyroid autoantibodies
Author: Kakizaki, H.
Takahashi, Y.
Iwaki, M.
Ichinose, A.
Selva-Nayagam, D.
Leibovitch, I.
Citation: Clinical Ophthalmology, 2011; 5(1):327-330
Publisher: Dove Medical Press Ltd
Issue Date: 2011
ISSN: 1177-5467
1177-5483
Statement of
Responsibility: 
Hirohiko Kakizaki, Yasuhiro Takahashi, Masayoshi Iwaki, Akihiro Ichinose, Dinesh Selva, Igal Leibovitch
Abstract: Purpose: To assess the effectiveness of the upper eyelid double motion sign in Graves’ orbitopathy (GO) in detecting thyroid dysfunction or a positive level of thyroid-related autoantibodies. Methods: GO was defined when more than two GO-related eyelid symptoms, including the double motion sign, existed with at least one positive thyroid-related blood test. Blood tests were performed in patients with more than two GO-related eyelid symptoms. The double motion was defined when the upper eyelid stopped at least once during downward eye movement. Fifty patients without GO or other eyelid diseases were used as controls. Results: There were 353 patients who showed more than two GO-related eyelid symptoms including the upper eyelid double motion sign. Of these, 300 patients were diagnosed with GO (300/353, 85.0%). The double motion sign was demonstrated in 267 patients (75.6%). A pause in double motion was typically seen around the anterosuperior direction of gaze. Double motion was not seen in any of the control eyelids. Although only 7.0% were hyperthyroid and 8.6% were hypothyroid, thyroid related autoantibodies were shown in 73.9% of patients. When the double motion sign was removed from the diagnostic criteria of GO, 263 patients had more than two thyroid-related eyelid symptoms, including 223 patients diagnosed as GO (25.7% reduction), although the rate of a correct diagnosis was almost the same (84.8%). Conclusions: The double motion sign of the upper eyelids is frequently demonstrated in GO patients. This previously unreported sign can help in detecting thyroid dysfunction states with positive levels of autoantibodies.
Keywords: GO
self-antibody
Rights: © 2011 Kakizaki et al, publisher and licensee Dove Medical Press Ltd. This is an Open Access article which permits unrestricted noncommercial use, provided the original work is properly cited.
DOI: 10.2147/OPTH.S17572
Published version: http://dx.doi.org/10.2147/opth.s17572
Appears in Collections:Aurora harvest
Opthalmology & Visual Sciences publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.