Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/69917
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Can bottle design prevent bacterial contamination of nasal irrigation devices?
Author: Foreman, A.
Wormald, P.
Citation: International Forum of Allergy and Rhinology, 2011; 1(4):303-307
Publisher: American Rhinologic Society
Issue Date: 2011
ISSN: 2042-6976
2042-6984
Statement of
Responsibility: 
Andrew Foreman and Peter-John Wormald
Abstract: <h4>Background</h4>Saline nasal irrigation is a mainstay in the medical management of chronic rhinosinusitis (CRS) with proven efficacy. However, bacterial contamination of irrigation bottles has recently been reported and this may contribute to recurrent infections. Sterilization is effective but could a change in bottle design obviate the need for regular sterilization?<h4>Methods</h4>A total of 20 stable CRS patients were given a NasalCare® (Techworld Corporation, Inc., Downington, PA) irrigation bottle to use regularly for 1 week. This bottle incorporates a 1-way valve to prevent irrigant regurgitation. Swabs were taken from their sinonasal cavity and 3 sites on the bottle-nozzle, valve, and inner surface.<h4>Results</h4>This study cultured a range of organisms from all sites of the bottle, including common CRS pathogens such as S. aureus, P. aeruginosa, and E. coli. Whereas the bottle's inner surface had the lowest bacterial recovery rate, the frequent culture of organisms at this site suggests a 1-way valve cannot completely prevent irrigant reflux. The high rate of organism detection at the nozzle and valve of the bottle is concerning, as bacteria at these sites may be transported to the nose during nasal douching.<h4>Conclusion</h4>Saline irrigation will continue to be an essential component of CRS management. However, despite employing a 1-way liquid valve in this study, nasal irrigation bottles can still become contaminated with bacteria. Thus, patient education, irrespective of bottle design, will be essential in preventing bacterial contamination of nasal irrigation devices. The results of our survey suggest this message is not getting across to our patients.
Keywords: bacteria
bottle
nasal
irrigation
contamination
Staphylococcus aureus
sinus
sinusitis
Rights: Copyright © 2011 American Rhinologic Society-American Academy of Otolaryngic Allergy, LLC
DOI: 10.1002/alr.20047
Published version: http://dx.doi.org/10.1002/alr.20047
Appears in Collections:Aurora harvest
Surgery publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.