Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/7498
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMavrangelos, C.-
dc.contributor.authorSwart, B.-
dc.contributor.authorNobbs, S.-
dc.contributor.authorNicholson, I.-
dc.contributor.authorMacardle, P.-
dc.contributor.authorZola, H.-
dc.date.issued2004-
dc.identifier.citationJournal of Immunological Methods, 2004; 289(1-2):169-178-
dc.identifier.issn0022-1759-
dc.identifier.issn1872-7905-
dc.identifier.urihttp://hdl.handle.net/2440/7498-
dc.description.abstractThe analysis of membrane molecules using antibodies detected by immunofluorescence staining and flow cytometry is used widely in research and diagnostic immunology. Conventional staining techniques readily detect molecules present at concentrations of around 2000 molecules per cell, but some molecules are expressed and function at much lower abundance. We described previously a method for the detection of molecules present at 100 molecules per cell or less based on the use of phycoerythrin as the fluorophore, a three-layer amplification process, and careful selection of available reagents. In recent years, a number of new reagents, fluorophores and kits, have become available, some of them intended for high-sensitivity applications. In this paper, a number of these reagents have been compared with the published method. While some of the reagents gave variable results or high nonspecific staining in our hands, several reagents were comparable with the published method. Furthermore, the new fluorophores allow improved simultaneous detection of two low-abundance markers.-
dc.language.isoen-
dc.publisherElsevier Science BV-
dc.source.urihttp://dx.doi.org/10.1016/j.jim.2004.04.016-
dc.subjectHumans-
dc.subjectImmunoglobulin G-
dc.subjectMembrane Proteins-
dc.subjectAntigens, CD-
dc.subjectAntibodies-
dc.subjectFluorescent Dyes-
dc.subjectIndicators and Reagents-
dc.subjectFluorescent Antibody Technique-
dc.subjectFlow Cytometry-
dc.titleDetection of low-abundance membrane markers by immunofluorescence - a comparison of alternative high-sensitivity methods and reagents-
dc.typeJournal article-
dc.identifier.doi10.1016/j.jim.2004.04.016-
pubs.publication-statusPublished-
Appears in Collections:Aurora harvest
Paediatrics publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.