Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/81205
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Variability of in vivo fluid dose distribution in mouse airways is visualized by high-speed synchrotron X-ray imaging
Author: Donnelley, M.
Morgan, K.
Siu, K.
Parsons, D.
Citation: Journal of Aerosol Medicine and Pulmonary Drug Delivery, 2013; 26(5):307-316
Publisher: Mary Ann Liebert Inc Publishers
Issue Date: 2013
ISSN: 1941-2711
1941-2703
Statement of
Responsibility: 
Martin Donnelley, Kaye S. Morgan, Karen K.W. Siu, and David W. Parsons
Abstract: <h4>Background</h4>The manner in which fluid instillations into mouse nose and lung distribute through the airways is poorly understood. Many agents are delivered in this way for testing as therapeutics, or as challenges designed to establish infections or create systemic drug delivery effects. These agents are delivered into mouse airways with little knowledge of the manner in which doses move through the airways, how long they reside in each region, and where the instilled materials eventually reach.<h4>Methods</h4>Synchrotron phase-contrast X-ray imaging (PCXI) was used to elucidate the primary controlling characteristics of mouse airway fluid dosing. High-speed image acquisition was used to track the movement of a range of bolus doses of an iodine-based contrast fluid through the nose (n=15) and lungs (n=10) of live anesthetized mice. For the lung studies, the mice were ventilated and paralyzed to control animal movement. Post-experiment image processing was used to visualize the fluid movement.<h4>Results</h4>The maximum dose that could be retained in only the anterior nose was ∼7.5 μL (20 g mouse), and a range of dynamic dose behaviors was documented after delivery. In the lung, the use of mechanical ventilation in combination with a paralytic agent prevented confounding artifactual movement, improving visualization of fluid progression through the airways. In the lung, optimized image analysis using the high image capture rate revealed the presence of respiratory pauses that could not be visualized at slower acquisition rates. The variability in the outcome of identical dose deliveries in different animals indicates that uniform lung distribution cannot be expected to occur with tracheal fluid delivery.<h4>Conclusions</h4>With adequate imaging rate and fluid dose parameters, this study shows the utility of synchrotron PCXI for determining the post-delivery behavior and fate of fluid doses such as those used in in vivo gene transfer or pharmaceutical studies.
Keywords: X-ray imaging
high resolution
mouse
airways
instillation
gene transfer
Rights: © Mary Ann Liebert, Inc.
DOI: 10.1089/jamp.2012.1007
Published version: http://dx.doi.org/10.1089/jamp.2012.1007
Appears in Collections:Aurora harvest 4
Paediatrics publications

Files in This Item:
File Description SizeFormat 
hdl_81205.pdfAccepted version260.62 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.