Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/97130
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMistry, R.-
dc.contributor.authorCaplash, Y.-
dc.contributor.authorGiri, P.-
dc.contributor.authorKearney, D.-
dc.contributor.authorWagstaff, M.-
dc.date.issued2015-
dc.identifier.citationPlastic and Reconstructive Surgery, Global Open, 2015; 3(3):e331-1-e331-4-
dc.identifier.issn2169-7574-
dc.identifier.issn2169-7574-
dc.identifier.urihttp://hdl.handle.net/2440/97130-
dc.descriptionCase Report-
dc.description.abstractWe present a patient with bilateral breast implant rupture who developed severe locoregional silicone granulomatous lymphadenopathy. Poly Implant Prothese silicone implants had been used for bilateral breast augmentation 5 years prior. Extracapsular implant rupture and bilateral axillary lymphadenopathy indicated explantation, capsulectomy, and selective lymph node excision. Histology demonstrated silicone lymphadenopathy with no evidence of malignancy. Over the subsequent 12 months, she developed progressive locoregional lymphadenopathy involving bilateral cervical, axillary, and internal mammary groups, resulting in bilateral thoracic outlet syndrome. We report the unusual presentation, progression, and the ultimate surgical management of this patient.-
dc.description.statementofresponsibilityRaakhi Mistry, Yugesh Caplash, Pratyush Giri, Daniel Kearney, Marcus Wagstaff-
dc.language.isoen-
dc.publisherWolters Kluwer Health-
dc.rightsCopyright © 2015 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of The American Society of Plastic Surgeons. All rights reserved. This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License, where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially.-
dc.source.urihttp://dx.doi.org/10.1097/gox.0000000000000295-
dc.titleThoracic outlet syndrome following breast implant rupture-
dc.typeJournal article-
dc.identifier.doi10.1097/gox.0000000000000295-
pubs.publication-statusPublished-
dc.identifier.orcidWagstaff, M. [0000-0003-3160-3720]-
Appears in Collections:Aurora harvest 7
Surgery publications

Files in This Item:
File Description SizeFormat 
hdl_97130.pdfPublished version466.87 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.