Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/132103
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Dynamic atrial substrate during high-density mapping of paroxysmal and persistent AF: implications for substrate ablation
Author: Wong, G.R.
Nalliah, C.J.
Lee, G.
Voskoboinik, A.
Prabhu, S.
Parameswaran, R.
Sugumar, H.
Anderson, R.D.
McLellan, A.
Ling, L.-H.
Morton, J.B.
Sanders, P.
Kistler, P.M.
Kalman, J.M.
Citation: JACC: Clinical Electrophysiology, 2019; 5(11):1265-1277
Publisher: Elsevier
Issue Date: 2019
ISSN: 2405-500X
2405-5018
Statement of
Responsibility: 
Geoffrey R.Wong, Chrishan J.Nalliah, Geoffrey Lee, Aleksandr Voskoboinik, Sandeep Prabhu, Ramanathan Parameswaran ... et al.
Abstract: OBJECTIVES:This study sought to determine the impact of rate and direction on left atrial (LA) substrate. BACKGROUND:The extent to which substrate mapped in sinus rhythm varies according to cycle length and direction of wave front propagation is unknown. METHODS:A total of 73 consecutive patients with atrial fibrillation (AF) underwent electroanatomic LA mapping before pulmonary vein isolation using multipolar catheter during distal coronary sinus (CS) pacing at 600 ms and 300 ms. Additional maps were created during left superior pulmonary vein pacing at 300 ms. Bipolar voltage, conduction velocity (CV), and complex signals were determined. RESULTS:Mean age was 61 ± 9 years, 67% were men, and 53% had persistent AF. Global mean voltage was lower with CS pacing at 300 ms compared with 600 ms (1.56 ± 0.47 mV vs. 1.74 ± 0.48 mV; p < 0.001). This was seen in all LA segments. Global CV was reduced (30.4 ± 13.0 cm/s vs. 38.6 ± 14.0 cm/s; p < 0.001) with greater complex signals at 300 ms (8.9% vs. 5.3%; p < 0.005). Compared with CS pacing, left superior pulmonary vein pacing demonstrated highly regional changes with decreased voltage (1.04 ± 0.43 mV vs. 1.47 ± 0.53 mV; p = 0.01) and CV (24.4 ± 13.0 cm/s vs. 39.9 ± 16.6 cm/s; p = 0.008), and greater complex signals posteriorly. Longer AF duration in paroxysmal AF (p = 0.02) and shorter duration in persistent AF (p = 0.015) and left ventricular ejection fraction (p = 0.016) were independent predictors of voltage change. CONCLUSIONS:In patients with AF, variation in cycle length and direction of wave front activation produce both generalized and regional changes in voltage, CV, and complex fractionation, resulting in significant changes in substrate maps. This study highlights the potential limitations of static low-voltage maps to identify the AF ablation target zone.
Keywords: direction-dependent conduction
Rights: © 2019 Published by Elsevier on Behalf of the American College of Cardiology Foundation
DOI: 10.1016/j.jacep.2019.06.002
Published version: http://dx.doi.org/10.1016/j.jacep.2019.06.002
Appears in Collections:Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.