Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/137351
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: Study protocol for Vascular Access outcome measure for function: a vaLidation study In hemoDialysis (VALID): A multi-center, multinational validation study to assess the accuracy and feasibility of measuring vascular access function in clinical practice
Author: Viecelli, A.K.
Teixeira-Pinto, A.
Valks, A.
Baer, R.
Cherian, R.
Cippà, P.E.
Craig, J.C.
DeSilva, R.
Jaure, A.
Johnson, D.W.
Kiriwandeniya, C.
Kopperschmidt, P.
Liu, W.J.
Lee, T.
Lok, C.
Madhan, K.
Mallard, A.R.
Oliver, V.
Polkinghorne, K.R.
Quinn, R.R.
et al.
Citation: BMC Nephrology, 2022; 23(1):372-1-372-12
Publisher: Springer Science and Business Media LLC
Issue Date: 2022
ISSN: 1471-2369
1471-2369
Statement of
Responsibility: 
Andrea K. Viecelli, Armando Teixeira, Pinto, Andrea Valks, Richard Baer, Roy Cherian, Pietro E. Cippà, Jonathan C. Craig, Ranil DeSilva, Allison Jaure, David W. Johnson, Charani Kiriwandeniya, Pascal Kopperschmidt, Wen, J Liu, Timmy Lee, Charmaine Lok, Krishan Madhan, Alistair R. Mallard, Veronica Oliver, Kevan R. Polkinghorne, Rob R. Quinn, Donna Reidlinger, Matthew Roberts, Bénédicte Sautenet, Lai Seong Hooi, Rob Smith, Maarten Snoeijs, Jan Tordoir, Tushar J. Vachharajani, Raymond Vanholder, Liza A. Vergara, Martin Wilkie, Bing Yang, Theodore H. Yuo, Li Zou, Carmel M. Hawley, and on behalf of the VALID Investigator Team
Abstract: BACKGROUND: A functioning vascular access (VA) is crucial to providing adequate hemodialysis (HD) and considered a critically important outcome by patients and healthcare professionals. A validated, patient-important outcome measure for VA function that can be easily measured in research and practice to harvest reliable and relevant evidence for informing patient-centered HD care is lacking. Vascular Access outcome measure for function: a vaLidation study In hemoDialysis (VALID) aims to assess the accuracy and feasibility of measuring a core outcome for VA function established by the international Standardized Outcomes in Nephrology (SONG) initiative. METHODS: VALID is a prospective, multi-center, multinational validation study that will assess the accuracy and feasibility of measuring VA function, defined as the need for interventions to enable and maintain the use of a VA for HD. The primary objective is to determine whether VA function can be measured accurately by clinical staff as part of routine clinical practice (Assessor 1) compared to the reference standard of documented VA procedures collected by a VA expert (Assessor 2) during a 6-month follow-up period. Secondary outcomes include feasibility and acceptability of measuring VA function and the time to, rate of, and type of VA interventions. An estimated 612 participants will be recruited from approximately 10 dialysis units of different size, type (home-, in-center and satellite), governance (private versus public), and location (rural versus urban) across Australia, Canada, Europe, and Malaysia. Validity will be measured by the sensitivity and specificity of the data acquisition process. The sensitivity corresponds to the proportion of correctly identified interventions by Assessor 1, among the interventions identified by Assessor 2 (reference standard). The feasibility of measuring VA function will be assessed by the average data collection time, data completeness, feasibility questionnaires and semi-structured interviews on key feasibility aspects with the assessors. DISCUSSION: Accuracy, acceptability, and feasibility of measuring VA function as part of routine clinical practice are required to facilitate global implementation of this core outcome across all HD trials. Global use of a standardized, patient-centered outcome measure for VA function in HD research will enhance the consistency and relevance of trial evidence to guide patient-centered care.
Keywords: Hemodialysis
Vascular access
Arteriovenous fistula
Arteriovenous graft
Central venous catheter
Validation
Feasibility
Core outcome
Patient engagement
Implementation
Rights: © Crown 2022. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http:// creat iveco mmons. org/ licen ses/ by/4. 0/. The Creative Commons Public Domain Dedication waiver (http:// creat iveco mmons. org/ publi cdoma in/ zero/1. 0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
DOI: 10.1186/s12882-022-02987-1
Grant ID: http://purl.org/au-research/grants/nhmrc/1092957
http://purl.org/au-research/grants/nhmrc/1196033
Published version: http://dx.doi.org/10.1186/s12882-022-02987-1
Appears in Collections:Medicine publications

Files in This Item:
File Description SizeFormat 
hdl_137351.pdfPublished version1.42 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.