Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/34704
Citations
Scopus Web of Science® Altmetric
?
?
Type: Journal article
Title: A novel nonobstructive intravascular MRI coil: in vivo imaging of experimental atherosclerosis
Author: Worthley, S.
Helft, G.
Fuster, V.
Fayad, Z.
Shinnar, M.
Minkoff, L.
Schecter, C.
Fallon, J.
Badimon, J.
Citation: Arteriosclerosis, Thrombosis and Vascular Biology, 2003; 23(2):346-350
Publisher: Lippincott Williams & Wilkins
Issue Date: 2003
ISSN: 1079-5642
1524-4636
Statement of
Responsibility: 
Stephen G. Worthley, Gérard Helft, Valentin Fuster, Zahi A. Fayad, Meir Shinnar, Lawrence A. Minkoff, Clyde Schechter, John T. Fallon, Juan J. Badimon
Abstract: <h4>Objective</h4>MRI is being used to characterize the composition of atherosclerotic plaques. However, the resolution achievable using surface radiofrequency coils is limited by the signal to noise ratio. We studied the utility of a new intravascular (IV) MRI probe for high-resolution in vivo imaging of atherosclerotic lesions.<h4>Methods and results</h4>Balloon-injured Watanabe heritable hyperlipidemic rabbits served as the experimental model of atherosclerosis. The newly developed IV MRI probe is 1.3 mm in diameter and can be positioned over a guidewire. MRI was performed with both an external phased-array coil and the IV MR coil. MR observations were correlated with histopathology. After MRI, the animals were killed and analysis of agreement between MR and histopathology was performed. The IV MR coil allows aortic images to be obtained with 156x156 micro m(2) in-plane resolution versus 352x352 micro m(2) when used with the external phased-array coil. No significant motion artifacts were noted, despite the continuation of arterial blood flow during image acquisition around the IV probe. The different components of the atherosclerotic lesions (lipid core and fibrous cap) were easily identified. There was an excellent agreement between MRI with the IV coil and histopathology by simple linear regression for both the mean wall thickness (r=0.88, slope 0.82, P<0.0001) and vessel wall area (r=0.86, slope 1.08, P<0.0001).<h4>Conclusions</h4>The new nonobstructive design for this intravascular coil provides great promise for additional work in high-resolution MRI characterization of atherosclerotic plaques in vivo. The ability to position the probe with a guidewire allows its placement under fluoroscopic or MRI guidance, whereas its size is compatible with human coronary arteries.
Keywords: atherosclerosis
intravascular
MRI
Description: © 2003 American Heart Association. All rights reserved.
DOI: 10.1161/01.ATV.0000053183.08854.A4
Published version: http://dx.doi.org/10.1161/01.atv.0000053183.08854.a4
Appears in Collections:Aurora harvest
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.