Title: Cardiac gated breath-hold black blood MRI of the coronary artery wall: an in vivo and ex vivo comparison
Author: Worthley, S.
Helft, G.
Fayad, Z.
Fuster, V.
Rodriguez, O.
Zaman, A.
Badimon, J.
Citation: International Journal of Cardiovascular Imaging, 2001; 17(3):195-201
Publisher: Springer Netherlands
Issue Date: 2001
ISSN: 1569-5794
1875-8312
Statement of
Responsibility: 
Stephen G. Worthley, Gérard Helft, Zahi A. Fayad, Valentin Fuster, Oswaldo J. Rodriguez, Azfar G. Zaman and Juan J. Badimon
Abstract: Background: High resolution magnetic resonance (MR) imaging of the coronary artery wall in vivo has been limited by the cardiac and respiratory motion, flow artifacts as well as the relatively small size of the coronary arteries. We sought to validate in vivo black blood MR imaging of the coronary artery wall using a double inversion recovery fast spin echo MR imaging sequence with limited breath-holding and cardiac gating for suppression of motion artifacts by comparison with ex vivo MR imaging. Methods: Yorkshire albino swine (n = 6) were used in this study and coronary lesions were induced with balloon angioplasty. Four weeks after balloon injury of the coronary arteries MR imaging of the coronary artery lesions was performed. High resolution in vivo and ex vivo images of the coronary artery wall and lesions were obtained using a double inversion recovery fast spin echo sequence in a 1.5 T MR system. There was a statistically significant agreement (p < 0.0001) between measurements of vessel wall area (r = 0.87, slope = 0.87) and maximal wall thickness (r = 0.84, slope = 0.88) from in vivo and ex vivo MR images of the coronary arteries. The mean differences between in vivo and ex vivo measurements were 0.56 ± 1.98 mm2 for vessel wall area and 0.02 ± 0.36 mm for maximal wall thickness. Conclusions: Using breath-holding and cardiac gating, it is possible to perform high resolution MR imaging of the coronary artery wall in vivo with good suppression of motion artifacts with a double inversion recovery fast spin echo black blood imaging sequence.
Keywords: coronary
motion suppression
MRI
Description: The original publication is available at www.springerlink.com
DOI: 10.1023/A:1010688122184
Published version: http://www.springerlink.com/content/q13319037n6nu246/
Appears in Collections:Aurora harvest
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.