Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/39216
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHsu, L.-
dc.contributor.authorJais, P.-
dc.contributor.authorHocini, M.-
dc.contributor.authorSanders, P.-
dc.contributor.authorRotter, M.-
dc.contributor.authorTakahashi, Y.-
dc.contributor.authorScavee, C.-
dc.contributor.authorSacher, F.-
dc.contributor.authorClementy, J.-
dc.contributor.authorHaissaguerre, M.-
dc.date.issued2005-
dc.identifier.citationPacing and Clinical Electrophysiology, 2005; 28(S1):S94-S98-
dc.identifier.issn0147-8389-
dc.identifier.issn1540-8159-
dc.identifier.urihttp://hdl.handle.net/2440/39216-
dc.descriptionThe definitive version is available at www.blackwell-synergy.com-
dc.description.abstractThe differentiation of pulmonary vein (PV) electrograms from atrial far-field signals during PV isolation (PVI) for atrial fibrillation (AF) may be difficult. In addition, owing to highly variable PV ostial sizes, current fixed-diameter circular PV mapping catheters may not yield optimal electrograms. We evaluated an expandable, circular 15–25 mm diameter, 20-pole mapping catheter for PV mapping during sustained AF in 25 patients. After selective PV angiography to define the ostial position and size, the catheter was introduced into each PV and withdrawn to the most stable proximal position, with optimal wall contact ensured by progressive loop expansion. At each PV ostium, electrograms recorded at high resolution (HR) were compared with those recorded at a resolution similar to that of a standard 10-pole Lasso catheter. After PVI performed during ongoing AF, the presence of residual far-field potentials (FFP) under both set-ups was compared. We mapped 97 PV, including 4 pairs with common ostia. In the HR recordings, the PV potentials had greater amplitude (0.5 ± 0.1 vs 0.3 ± 0.1 mV, P = 0.001) and fragmentation, whereas left atrial FFP were minimized. After successful isolation of all PV, FFP were observed in 33% of left superior and 28% of left inferior PV on the HR recordings, compared to 66% and 61%, respectively under normal resolution. Catheter stability and optimal wall contact, in combination with HR electrograms can optimize circumferential PV mapping during AF and improve the discrimination of FFP postablation.-
dc.description.statementofresponsibilityLi-Fern Hsu, Pierre Jaïs, Mélèze Hocini, Prashanthan Sanders, Martin Rotter, Yoshihide Takahashi, Christophe Scavée, Frederic Sacher, Jacques Clémenty, Michel Haïssaguerre-
dc.language.isoen-
dc.publisherFutura Publ Co-
dc.source.urihttp://www.blackwell-synergy.com/doi/abs/10.1111/j.1540-8159.2005.00061.x-
dc.subjectatrial fibrillation-
dc.subjectcatheter ablation-
dc.subjectcardiac mapping-
dc.subjectpulmonary veins-
dc.subjectfar-field electrograms-
dc.titleHigh-density circumferential pulmonary vein mapping with a 20-pole expandable circular mapping catheter-
dc.typeJournal article-
dc.identifier.doi10.1111/j.1540-8159.2005.00061.x-
pubs.publication-statusPublished-
dc.identifier.orcidSanders, P. [0000-0003-3803-8429]-
Appears in Collections:Aurora harvest
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.