Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/78916
Citations
Scopus Web of Science® Altmetric
?
?
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGong, J.-
dc.contributor.authorLambert, M.-
dc.contributor.authorSimpson, A.-
dc.contributor.authorZecchin, A.-
dc.date.issued2013-
dc.identifier.citationJournal of Hydraulic Engineering, 2013; 139(6):645-655-
dc.identifier.issn0733-9429-
dc.identifier.issn1943-7900-
dc.identifier.urihttp://hdl.handle.net/2440/78916-
dc.description.abstractHydraulic transients (water hammer waves) can be used to excite a pressurized pipeline, yielding the frequency response diagram (FRD) of the system. The FRD of a pipeline system is useful for condition assessment and fault detection, because it is closely related to the physical properties of the pipeline. Most previous FRD-based leak detection techniques use the sinusoidal leak-induced pattern recorded on the FRD, either shown on the resonant responses or the antiresonant responses. In contrast, the technique reported in the current paper only uses the responses at the first three resonant frequencies to determine the location and size of a leak. The bandwidth of the excitation only needs to be five times that of the fundamental frequency of the tested pipeline, which is much less than the requirement in conventional FRD-based techniques. Sensitivity analysis and numerical simulations are performed to assess the robustness and applicable range of the proposed leak location technique. The proposed leak location technique is verified by both numerical simulations and by using an experimental FRD obtained from a laboratory pipeline. © 2013 American Society of Civil Engineers.-
dc.description.statementofresponsibilityJinzhe Gong, Martin F. Lambert, Angus R. Simpson, and Aaron C. Zecchin-
dc.language.isoen-
dc.publisherASCE-Amer Soc Civil Engineers-
dc.rights© 2013 American Society of Civil Engineers-
dc.source.urihttp://dx.doi.org/10.1061/(asce)hy.1943-7900.0000720-
dc.subjectPipelines-
dc.subjectFluid transients-
dc.subjectWater hammer-
dc.subjectWater distribution systems-
dc.subjectLeak detection-
dc.subjectFrequency response diagram-
dc.subjectHarmonic analysis.-
dc.titleSingle-event leak detection in pipeline using first three resonant responses-
dc.typeJournal article-
dc.identifier.doi10.1061/(ASCE)HY.1943-7900.0000720-
dc.relation.granthttp://purl.org/au-research/grants/arc/DP1095270-
dc.relation.granthttp://purl.org/au-research/grants/arc/DP1095270-
pubs.publication-statusPublished-
dc.identifier.orcidGong, J. [0000-0002-6344-5993]-
dc.identifier.orcidLambert, M. [0000-0001-8272-6697]-
dc.identifier.orcidSimpson, A. [0000-0003-1633-0111]-
dc.identifier.orcidZecchin, A. [0000-0001-8908-7023]-
Appears in Collections:Aurora harvest 7
Civil and Environmental Engineering publications
Environment Institute publications

Files in This Item:
File Description SizeFormat 
hdl_78916.pdfAccepted version403.59 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.