Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/9876
Citations
Scopus Web of ScienceĀ® Altmetric
?
?
Type: Journal article
Title: Validation of fully automatic brain SPET to MR co-registration
Author: Barnden, L.
Kwiatek, R.
Lau, Y.
Hutton, B.
Thurfjell, L.
Pile, K.
Rowe, C.
Citation: European Journal of Nuclear Medicine and Molecular Imaging, 2000; 27(2):147-154
Publisher: Springer-Verlag
Issue Date: 2000
ISSN: 1619-7070
0340-6997
Statement of
Responsibility: 
Leighton Barnden, Richard Kwiatek, Yiu Lau, Brian Hutton, Lennart Thurfjell, Kevin Pile and Christopher Rowe
Abstract: Fully automatic co-registration of functional to anatomical brain images using information intrinsic to the scans has been validated in a clinical setting for positron emission tomography (PET), but not for single-photon emission tomography (SPET). In this paper we evaluate technetium-99m hexamethylpropylene amine oxime to magnetic resonance (MR) co-registration for five fully automatic methods. We attached six small fiducial markers, visible in both SPET and MR, to the skin of 13 subjects. No increase in the radius of SPET acquisition was necessary. Distortion of the fiducial marker distribution observed in the SPET and MR studies was characterised by a measure independent of registration and three subjects were excluded on the basis of excessive distortion. The location of each fiducial marker was determined in each modality to sub-pixel precision and the inter-modality distance was averaged over all markers to give a fiducial registration error (FRE). The component of FRE excluding the variability inherent in the validation method was estimated by computing the error transformation between the arrays of MR marker locations and registered SPET marker locations. When applied to the fiducial marker locations this yielded the surface registration error (SRE), and when applied to a representative set of locations within the brain it yielded the intrinsic registration error (IRE). For the best method, mean IRE was 1.2 mm, SRE 1.5 mm and FRE 2.4 mm (with corresponding maxima of 3.3, 4.3 and 5.0 mm). All methods yielded a mean IRE <3 mm. The accuracy of the most accurate fully automatic SPET to MR co-registration was comparable with that published for PET to MR. With high standards of calibration and instrumentation, intra-subject cerebral SPET to MR registration accuracy of <2 mm is attainable.
Keywords: Image registration
Validation
Multi-modality images
Single-photon emission tomography
Magnetic resonance
Description: The original publication can be found at www.springerlink.com
DOI: 10.1007/s002590050020
Published version: http://dx.doi.org/10.1007/s002590050020
Appears in Collections:Aurora harvest 4
Medicine publications

Files in This Item:
There are no files associated with this item.


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.