Please use this identifier to cite or link to this item: https://hdl.handle.net/2440/64721
Type: Thesis
Title: Evaluation of normal tissue complication probability and risk of second primary cancer in prostate radiotherapy.
Author: Takam, Rungdham
Issue Date: 2010
School/Discipline: School of Chemistry and Physics
Abstract: The probabilities of developing radiation-induced normal tissue complications and second primary cancers were evaluated using dose-volume histograms as well as dose measurements covering a range of radiotherapy techniques including External Beam Radiotherapy (EBRT) and Brachytherapy (BT) for prostate cancer. There are two major parts in this thesis. In the first part, the Dose-Volume Histograms (DVHs) of the Organs-At-Risk (OARs) such as rectum, bladder, urethra, and femoral heads were retrieved from the radiation treatment plans of 4-field standard fractionated (2 Gy/fraction) Three-Dimensional Conformal Radiotherapy (3D-CRT) to total dose of 64 Gy, 4-field hypofractionated (2.75 Gy/fraction) 3D-CRT to total dose of 55 Gy, 5-field 3D-CRT to total dose of 70 Gy, 4-field 3D-CRT to total dose of 70 and 74 Gy, Low-Dose-Rate Brachytherapy (LDR-BT) with I-125, High-Dose-Rate Brachytherapy (HDR-BT) with Ir-192, and combined-modality treatment (3D-CRT & HDR-BT) techniques. The DVHs of these normal organs/tissues were converted to Biologically Effective Dose based DVHs (BEffDVHs) and Equivalent Dose based DVHs (DeqVHs) respectively in order to account for differences in radiation treatment modality and fractionation schedule. For assessment of the Normal Tissue Complication Probability (NTCP), the Lyman and Relative Seriality NTCP models were applied to the differential DeqVHs of the OARs. For the assessment of risk of radiation-induced Second Primary Cancer (SPC), the Competitive Risk model was used. In total, 223 DVHs from 101 patients were analysed in this thesis. In the second part, a radiation dosimetry technique was developed and used in measuring the doses delivered to distant organs/tissues (e.g. lungs and thyroid) as a result of prostate irradiation. In this case, simulation of prostate cancer radiotherapy was performed with the anthropomorphic Rando phantom using 4-field 3D-CRT technique to the total dose of 80 Gy with the 18 MV X-ray beam from Varian iX linear accelerator (linac). Radiation doses at different locations in the Rando phantom resulting from scattered and leakage photon and neutron radiations were measured using enriched 6Li and 7Li LiF:Mg,Cu,P glass-rod thermoluminescence dosimeters (TLDs). Results indicated that with hypofractionated 3D-CRT (20 fractions of 2.75-Gy fraction and 5 times/week to total dose of 55 Gy) NTCP of rectum, bladder and urethra were less than those for standard fractionated 3D-CRT using 4-field technique (32 fractions of 2-Gy fraction and 5 times/week to total dose of 64 Gy) and dose-escalated 3D-CRT. Rectal and bladder NTCPs (5.2% and 6.6% respectively) following the dose-escalated 4-field 3D-CRT (2 Gy per fraction to total dose of 74 Gy) were the highest amongst the analysed treatment techniques. The average NTCP for rectum and urethra were 0.6% and 24.7% for LDR-BT and 0.5% and 11.2% for HDR-BT. Although brachytherapy techniques resulted in delivering larger equivalent doses to normal tissues, the corresponding NTCPs were lower than those of external beam techniques except in the case of urethra due to much smaller volumes irradiated to higher doses. Amongst normal tissues analysed, femoral heads were found to have the lowest probability of complications as most of their volume was irradiated to lower equivalent doses compared to other tissues. The average estimated radiation-induced SPC risk was no greater than 0.6% for all treatment plans corresponding to various treatment techniques but was lower for either LDR or HDR brachytherapy alone compared with any EBRT technique. For LDR and HDR brachytherapy alone, the risk of SPC for rectum was approximately 2.0 x 10-4% and 8.3 x 10-5% respectively compared with 0.2% for EBRT using 5-field 3D-CRT to total dose 74 Gy. Treatment plans which deliver equivalent doses of around 3 – 5 Gy to normal tissues were associated with higher risks of development of cancers. Results from TLDs measurements in the Rando phantom indicated that photon doses were highest close to the irradiation volume and the photon dose equivalent ratio (dose equivalent per unit of target dose) decreases proportionally with the distance from the isocentre (e.g. 6.5 mSv/Gy for small intestine to 0.2 mSv/Gy for thyroid). In contrast, the dose equivalent ratio of neutrons in the Rando phantom was observed to be constant at approximately 5.7 mSv/Gy for up to 50 centimeters from the edge of the treatment field (from pancreas to oesophagus). The total dose equivalent (photon and neutron) for each organ/tissue approximated for the 4-field standard fractionated 3D-CRT technique to total dose of 80 Gy using 18 MV X-ray beam from Varian iX linac ranged between 323.0 mSv (for thyroid) and 1203.7 mSv (for colon). Based on the competitive risk model and on the assumptions that the dose equivalents were uniformly distributed in the volumes of these organs/tissues, the estimated risks of SPC range from 1.5% (in thyroid) up to 4.5% (in colon). Different radiation treatment techniques for prostate cancer are associated with different probabilities of developing radiation-induced normal tissue complications and second primary cancers. In the case of brachytherapy for prostate cancer, due to its specific dose-volume characteristics in addition to not having the leakage or neutron radiation associated with external beam radiotherapy, this treatment modality is associated with a reduced risk of NTCP and SPC compared with EBRT techniques for both organs situated close to and organs situated at a distance from the treatment field. In this current work, the radiation dosimetry technique based on the 6LiF:Mg,Cu,P and 7LiF:Mg,Cu,P glass-rod TLDs was developed to determine the radiation doses received by organs/tissues positioned away from the irradiation field due to scattered and leakage photons and neutrons. This radiation measurement technique enables the evaluation of the prostate radiation treatment plan to include the assessment of organs/tissues of interest in both high and low dose regions. It was demonstrated in this thesis that the relative seriality (NTCP) and the competitive risk (SPC) are useful models which can be used for the purpose of relative comparison and evaluation of prostate radiation treatment plans even though they may need to be further verified and fine tuned against clinical data.
Advisor: Bezak, Eva
Yeoh, Eng Kiat
Dissertation Note: Thesis (Ph.D.) -- University of Adelaide, School of Chemistry and Physics, 2010
Keywords: NTCP; second cancer; prostate radiotherapy
Provenance: Copyright material removed from digital thesis. See print copy in University of Adelaide Library for full text.
Appears in Collections:Research Theses

Files in This Item:
File Description SizeFormat 
01front.pdf752.75 kBAdobe PDFView/Open
02chapters1-3.pdf2.26 MBAdobe PDFView/Open
03chapter4.pdf1.43 MBAdobe PDFView/Open
04chapters5-6.pdf2.53 MBAdobe PDFView/Open
05chapters7-8.pdf1.71 MBAdobe PDFView/Open
06bibliography.pdf937.56 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.